3.4 Replacing rotating gobos
DANGER!
Replace gobos with the device switched off only.
Unplug from mains before!
1. Disconnect the xture from mains and allow it to cool.
2. Remove the bottom plastic cover of the head by loosening the 4 quarter-turn fasteners on the cover.
3. Gently pull up the gobo holder from the rotation gobo wheel
.
4. Carefully remove the gobo and the spring gobo-lock from the gobo holder by pushing to the gobe from the side
without toothed wheel
t. Do not touch the surface of the pattern of the glass gobo - use a suitable glove.
Be careful! Glass!
5. Insert the new gobo (glazy side towards the lamp). Insert the spring-gobo lock
to secure it in the gobo holder.
6. Insert the gobo holder back into rotating gobo wheel
.
5. Replace the bottom cover before applying power.